IMH
Inductive strip position measurement in furnaces
In continuous strip annealing lines with either horizontal or vertical strip passage and furnace temperatures of up to 1000 °C, the inductive IM system measures the strip centre position with an accuracy of ± 5 mm. Two temperature-resistant metal tubes equipped with special heat-resistant measuring coils are installed across the furnace above and below the strip. The electrical cables between the measuring coils and the evaluation electronics outside the furnace are sealed so as to be gas-tight. Depending on the selected centre position sensors, the system may be used for sensing centre deviations on strip having a width of 450, 1050 or 1450 mm.


Burn-in-test of inductive coils at the inhouse furnace at EMG