Sensor family SMI

SMI-SE for standard applications

[Translate to English:] SMI-SE

Application:
Strip centre guiding system for operation at normal ambient temperatures

Design:
Compact measuring frame with integrated evaluation electronics. Optionally available with a 30 m connecting cable for remote mounting of the evaluation electronics.

Sensor types:
SMI-SE / 150 Accuracy +/- 2 mm; max. change in width 300 mm
SMI-SE / 300 Accuracy +/- 2 mm; max. change in width 600 mm
SMI-SE / 500 Accuracy +/- 3 mm; max. change in width 1000 mm
SMI-SE / 750 Accuracy +/- 3 mm; max. change in width 1500 mm
SMI-SE / 900 Accuracy +/- 5 mm; max. change in width 1800 mm

SMI-HE for high-precision measurement

[Translate to English:] SMI-HE

Applications:
Strip centre guiding system for operation at normal ambient temperatures

Design:
Compact measuring frame with integrated evaluation electronics. Optionally available with a 30 m connecting cable for remote mounting of the evaluation electronics.

Sensor types:
SMI-HE / 150 Accuracy +/- 1 mm; max. change in width 300 mm
SMI-HE / 300 Accuracy +/- 1 mm; max. change in width 600 mm
SMI-HE / 500 Accuracy +/- 1 mm; max. change in width 1000 mm
SMI-HE / 750 Accuracy +/- 1 mm; max. change in width 1500 mm
SMI-HE / 900 Accuracy +/- 3 mm; max. change in width 1800 mm

SMI-LE for enhanced mechanical requirements

Application:
Strip centre guiding system for use at normal ambient temperatures, with frame reinforcements for enhanced mechanical requirements, such as on a looper car.

Design:
Compact measuring frame with integrated evaluation electronics. Optionally available with a 30 m connecting cable for remote mounting of the evaluation electronics.

Sensortypes:
SMI-LE / 500 Accuracy +/- 3 mm; max. change in width 1000 mm
SMI-LE / 750 Accuracy +/- 3 mm; max. change in width 1500 mm
SMI-LE / 900 Accuracy +/- 5 mm; max. change in width 1800 mm

SMI3 for strip temperatures of up to 300 °C

[Translate to English:] SMI3

Application:
Strip centre guiding system for strip temperatures of up to 300 °C (max. 130 °C at the sensors); centre measuring accuracy +/- 5 mm.

Design:
Compact measuring frame with thermal shielding and separate evaluation electronics.

Sensor types:
SMI3-SR / 400 Accuracy +/- 5 mm; max. change in width 600 mm
SMI3-SR / 600 Accuracy +/- 5 mm; max. change in width 1050 mm
SMI3-SR / 800 Accuracy +/- 5 mm; max. change in width 1450 mm